Our Third Party Testing Bodies: LLOYDS BRITISH, ICAS, SGS
Flame retardant, antistatic, high strength
Non rusting, non discoloration, anti-aging
Convenient construction and maintenance
The cable can be controlled and communicated according to electric power
Layered laying of communications, anti-coupling
High temperature press SMC sheet molding compounds
Acid and alkali resistance, corrosion resistance
Avatar SMC Performance index
Anti slip pattern
Avatar cover of composite access covers achieved a market leading Skid Resistance Value of 89
The table below has been developed from data collected by County
Surveyors Society and illustrates the acceptabable parameters when tested using the TRRL Pendulum Test in general accordance with BS667:part 1:1986
This test provides a slip resistance value(SRV) for each surface tested The higher value the greater slip resistance.
TRRL Pengulum Value | Condition Of Surface |
19 and below | Dangerous |
20-39 | Marginal |
40-74 | Satisfactory |
Adove75 | Excelient |
UV resistance test
Table 3-1 Ultravioler Test Conditions Standard Source Duration of Exposure ASTM G154
Table 3-1 Ultraviolet Test Conditions
Standard | Source | Duratlon of Exposure |
ASTM G154a(Cycle 1) | UVA:340nm | 2,160hours |
ASTM G154b(Cycle 1) | Xenon Arc:340nm | 1,000hours |
ASTM G154(Cycle 3)c | UVB:Type313 | 2,160hours |
Results summary | ||
Average Flexural Strength Before UV aging (MPa) | Average Flexural Strength After UV aging (MPa) | Average Flexural Strength due to UV aging(%) (MPa) |
910 | 820 | 10 |
The loss of flexural strength was measured to be approximately 10%
Flame retardant grade
The flame retardant grade is FV0,(the highest grade of non-metallic mateials),and the smoke emission level is 15 when burned at high temperatures.The smoke is non-toxic,and the ttoxicity level is ZA1,which is considered safe ievel one.
Different installation positions are divided into groups numbered 1 to 2.
Figures 2 and 3 show the installation position of the trench cover plate in the railway lane.(Group 1:A10 Class)
Figure 2 is capable of bearing a laboratory load of 10KN, only suitable for cabletrenchuse.(Group 2:A15 Class).
Figure.3 is capable of bearing a laboratory load of 50KN and suitable for use as walkway, allowing pedestrian access. (Group 3: B80 Class)
Figure 3 can withstand a laboratory load of 80KN and suitable for use as walkway, allowing pedestrian and small vehicle access